Products

disable

disable

  • :disable
  • :Radiale loodgeleide MLCC (monolitiese keramiekkapasitor)
  • :-
  • :-
  • :YES
  • :

50V 105M 1UF 5.08mm ±20% Radial Lead MLCC 

APPROVAL SPECIFICATION FOR LEADED TYPE MLCC




1.FEATURES:
 

Lead Type Code




Part number CD2A104KC9IER1E000
Description 100V/104/K/F5.08/小平头/L24/X7R(Ⅱ)/0805
Customer P/N  
Dielectric class Class 2
Rated voltage 100Vdc
Capacitance 0.1uF ±10% @ 1kHz 1.0V 25ºC
Tangent of loss angle 0.035 max @ 1kHz 1.0V 25ºC
Testing voltage 250Vdc (Charge/discharge 2mA max) 3s PASS
Insulation resistance 1000MΩ min @ 100V 60s, RH≤70%
Temperature characteristics X7R(Ⅱ) ΔC/C: ±15% @ -55ºC~125ºC
W (Weight) 5mm max
H (Height) 4.2mm max
T (Thickness) 3.2mm max
F (Lead spacing) 5.08mm±0.8mm
L (Lead length) 24mm±4.0mm
ød (Lead diameter) 0.45mm±0.05mm
Marking 104

 
2.GENERAL:

1)This specification applies to the leaded type MLCC for the electronic equipment.
2)Leaded type MLCC
Leaded type MLCC is a capacitor with a multilayer ceramic capacitors soldering lead wire and coating epoxy
resin.It has the following characteristics
■Miniature size, large capacitance, tape and reel packaging suitable for auto-placement.
■Epoxy resin coating creates excellent performance in humidity resistance, mechanical strength and heat resistance.
■Standard size, various lead configurations.
3)Complies with RoHS 2.0


3.APPLICABLE STANDARD

This product complies with the following standards, and the relevant content of this specification refers to the
following standards when the two sides in dispute the following criteria for arbitration
GB/T 2693-2001 Fixed capacitors for use in electronic equipmen — Part 1: Generic specification (IDT IEC
60384-1)
GB/T 5966-2011 Fixed capacitors for use in electronic equipmen — Part 8: Sectional specification: Fixed
capacitors of ceramic dielectric, Class 1 (IDT IEC 60384-8)
GB/T 5968-2011 Fixed capacitors for use in electronic equipmen — Part 9: Sectional specification: Fixed
capacitors of ceramic dielectric, Class 2 (IDT IEC 60384-9)


4.MEASUREMENT AND TEST

No. Item Specifications Testing Method
1 Operating temp. range -55ºC~125ºC  
2
Rated voltage
(U R )
100V
The rated voltage is defined as the maximum voltage which may be applied
continuously to the capacitor within the operating temperature range.
When AC voltage is superimposed on DC voltage, Vp-p or Vo-p, whichever is
larger, should be maintained within the rated voltage range.
3
Appearance (APP)
and Dimension
No marked defect on appearance form and
dimensions are within specified range.
The capacitor should be visually inspected for evidence of defect.
Dimensions should be measured with slide calipers.
4 Marking To be easily legible. The capacitor should be visually inspected.
5 Capacitance (C R ) 100000pF±10% 
The capacitance, tanδ should be measured at 25°C±1°C with the following
conditions. 1kHz 1.0Vrms
6 Tangent of loss angle (tanδ) 0.035 max Same as above
7
Insulation Resistance
(IR)
1000MΩ min
The insulation resistance should be measured with a DC voltage not exceeding
the following voltage at normal temperature and humidity and less than 1 minute
of charging. 100VDC
8
Testing Voltage
(TV)
No failure.
The capacitor should not be damaged when test voltages of below are applied
between the lead wires for 1 to 5 sec.(Charge/Discharge current ≤ 2mA) 250VDC
9 Terminal Tensile Strength
Lead wire should not be cut off capacitor
should not be broken.
Fix the body of the capacitor and apply a tensile weight gradually to each lead
wire in the radial direction of the capacitor up to 10N and keep it for 10±1 sec.
10 Terminal Bending Strengt
Lead wire should not be cut off capacitor
should not be broken.
Each lead wire should be subjected to 5N of weight and bent 90° at the point of
egress, in one direction, then returned to its original position and bent 90° in the
opposite direction at the rate of one bent in 2 to 3 sec.
11 Solderability of Leads
Lead wire should be soldered with uniform
coating on the axial direction over 3/4 of the
circumferential direction.
The lead wire of a capacitor should be dipped into molten solder for 3±0.5 sec.
The depth of immersion is up to about 1.5 to 2.0mm from the root of lead wires.
Temp. of solder: Lead Free Solder (Sn-3Ag-0.5Cu) 245±5°C
H63 Eutectic Solder 235±5°C
12 Soldering Effect APP:No marked defect
ΔC/C:±10%
IR:More than 30% initial specified value.

 
The lead wires should be immersed in solder of 260±5°C up to 1.5 to 2.0mm
from the root of terminal for 3.5±0.5 sec.
Post-treatment:
Capacitor should be stored for 12 h at room condition.
13
Vibration
Resistance
APP:No marked defect
Cr:Per Item 5.
tanδ:Per Item 6. 
The capacitor should be firmly soldered to the supporting lead wire and vibrated
at a frequency range of 10 to 55Hz, 1.5mm in total amplitude, with about a 1
minute rate of vibration change from 10Hz to 55Hz and back to 10Hz.
Apply for a total of 6 hours, 2 hours each in 3 mutually perpendicular directions.
14 Temperature characteristics ΔC/C: ±15%
The capacitance measurement should be made at each step specified in below.
Stwp Temperature (±1ºC)
1 +20
2 -55 (Y5V: -30)
3 +20
4 +125 (Y5V, X5R: +85)
5 +20
15
Humidity
Loading
APP:No marked defect
ΔC/C:±10%
tanδ:Less than 200% initial specified value.
IR:More than 25% initial specified value.
Apply the rated voltage for 500±12 hours at 40±2°C in 90 to 95% relative
humidity.
Post-treatment:
Capacitor should be stored for 24 h at room condition.
16
High
Temperature
Load
APP:No marked defect
ΔC/C:±10%
tanδ:Less than 150% of initial specified value.
IR:More than 50% initial specified value.
Apply a DC voltage of 150% of the following voltage for 1000+48/-0 hours at
125±2°C (X5R, Y5V: 85°C) with a relative humidity of 50% max.
(Charge/discharge current ≤2mA)
150VDC
Post-treatment: Capacitor shall be stored for 24 h at room condition.
17
Temperature and
Immersion Cycle
APP:No marked defect
ΔC/C:±10%
tanδ:Less than 150% of initial specified value.
IR:More than 30% initial specified value.
Temperature cycling shall be measured in the following test.
Step   Temperature                  Time
1        -25±2°C                          30min
2  +125±2°C(X5R, Y5V: 85°C) 30min
Cycle times: 5 cycles
Post-treatment: Capacitor shall be stored for 12 h at room condition.
 

5.PACKAGING AND STORAGE

PACKAGING:
Taping of ammo packing, 2000 pcs/box (20 000 pcs/carton)
Bulk packing, 1000 pcs/bag (Depending on the disc size, each carton is 20 000~100 000pcs)

STORAGE ENVIRONMENT
The insulating coating of capacitors does not form a perfect seal; therefore, do not use or store capacitors in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. And avoid exposure to moisture. Store the capacitors where the temperature and relative humidity do not exceed 5 to 40 degrees centigrade and 15 to 70%.


6.MEASURING AND APPLICATION NOTICE
 
Mesurement notice:
Please measure under the following conditions.

Standard atmospheric conditions
 
Unless otherwise specified, all tests and measurements shall be made under standard atmospheric conditions for testing as
given in 
5.3 of IEC 60068-1.
Before the measurements are made, the capacitor shall be stored at the measuring temperature for a time sufficient to allow the
entire capacitor to reach this temperature. The period as prescribed for recovery at the end of a test is normally sufficient for this
purpose.

Test and measurement shall be made under standard atmospheric conditions for testing, in the event of a dispute, the
measurements shall be repeated using one of the referee temperatures (as given in 7.1.3).
When tests are conducted in a sequence, the final measurements of one test may be taken as the initial measurements for the
succeeding test.

Recovery conditions:
Unless otherwise specified recovery shall take place under the standard atmospheric conditions for testing (7.1.1).

If recovery under closely controlled conditions is necessary, the controlled recovery conditions of 5.4.1 of IEC 60068-1 shall be
used.

Referee conditions:

For referee purposes, one of the standard atmospheric conditions for referee tests taken from 5.2 of IEC 60068-1, as given in
table 1 below, shall be selected:

Operating voltage:
The voltage applied to the capacitor must not exceed the rated voltage.

 

: HV Ceramic Capacitors

: +86 13689553728

: +86 13689553728

: sales@hv-caps.com

: 深圳市福田区天安数码城天翔大厦9B2

+86 13689553728
sales@hv-caps.com